Product
OPTICAL WORKSTATION


product description:

GSON600 Workstations for two-way HFC FTTB engineering applications, the last stage uses GaAs module output, with four high-output, can greatly reduce equipment and customer premises optical node between, improve the reliability of the network, directly to the 400 ~ 500 users with high index signals. And the unit is equipped with state monitoring interface that can monitor the machine/s operating voltage, current, optical received power, optical transmission power, the group transform voltage, radio frequency and other parameters indicators. And reverse channels -6dB, all-pass, remote setting off three states.

Features:

Efficient switching power supply. Enter an optional power supply AC220V, 60V. Centralized power supply with a 60V input port;

Wild-type chassis, excellent water resistance and electromagnetic shielding performance;

Optical AGC function, the input optical power -8 ~ + when 2dBm, the output level constant;

Low optical power receiving input optical power to ensure the machine performance when -5dBm;

10 LED display rows of lights, displays the current input optical power, 1dBm step;

Each port has lightning and surge voltage protection;

With a variety of output types, optional independent, bridges and distribution output;

Balanced inserts and attenuators common, both British attenuator, convenient debugging;

Optional Installation Class I or Class II network management responder, remote monitoring equipment operation.


Technical Parameters:
Optical workstation performance parameters of the forward path optical receiver

project

unit

Performance parameters

Input optical power range

dBm

-6~+1

Operating wavelength

nm

1290~1600

Optical Return Loss

dB

≥45

flatness

dB

±0.75

Output Level

dBuV

4 outputs ≥108

C/N

dB

≥51

CTB

dBc

≥65

CSO

dBc

≥61

Frequency Range

MHz

85-862(1003)

Optical Connector Style

 

FC/APC

RF output impedance

Ω

75

RF output return loss

dB

≥16(47-862 MHz), ≥14(862-1003 MHz)

Dimensions

mm

GSON600D:350(L)*210(W)*170(H)
>GSON600C:280(L)*230(W)*110(H)

RF amplification optical workstation performance parameters

project

unit

Performance parameters

Forward

Reverse

bandwidth

MHz

47/87—750/862

5—30/65

flatness

dB

±0.75

±0.75

Return Loss

dB

≥16(47—862MHz)

≥16

Minimum full gain

dB

≥26

17—24

Noise factor

dB

≤10

≤14

CTB

dB

≥68 (silicon power doubler)
≥76 (GaAs)

≥78 (6-way CW carrier)

CSO

dB

≥68 (silicon power doubler)
≥74 (GaAs)

≥73 (6-way CW carrier)

Detecting port

dB

-20±1.5

-20±1.5

Note: 1, RF amplification of nonlinear index is within the 550MHz frequency range, configuration 59 Road PLA-D channel, so that the port RF output level 108dBuV, tilt the worst value in the state when the test result of 12dB 862MHz bandwidth.
2, the entire distortion indicator light station depends on the optical transmitter and optical receiver unit and the RF amplification of the entire link.

Reverse transmission performance parameters

project

unit

Performance parameters

Remark

Optical wavelength

nm

1310±20

 

Optical power

mW

1∽3

Mitsubishi

Return Loss

dB

≥16

 

flatness

dB

±0.75

 

Frequency Range

MHz

5-65

 

Standard gain

dB

25

 

Hum than signal

%

<2

 

Recommended RF input level

dBuV

75

Optimum operating point

The optical connector form

 

FC/APC

Optional SC / UPC

Noise Power Ratio (NPR) Dynamic Range

dB

≥15(NPR≥30dB)

Link index finger upstream optical transmitter and upstream optical receiver and other components

Note: 1, four signal method, 19,25,31 MHz; 2, two signal method, 13,19MHz; 3, tested using standard receiver, 10dB link loss.

Optical Workstation System Specifications

project

unit

System characteristics Index

C/N

dB

51

CTB

dBc

65

CSO

dBc

61

Link flatness

dB

±0.75

Total power consumption

W

≤60

NOTE: The standard transmitter, the input optical power -1dBm, PAL-D path 59 is configured in the 550MHz range channels, RF output signal inclined 6dB (862MHz), the output level is 104dBuV (GaAs 108dBuV) test.

Ordering Guide:

GSON600

0

0

0

0

GSD Field type optical workstation

D: 4 independent outputs
C: 4-way distribution outputs

8: 862 MHz Bandwidth
1: 1GHz Bandwidth

F: FP laser
D: DFB lasers

FC:FC/APC
SC:SC/APC

Failure Analysis:
1, the optical power receiving indicator red normal, steady light power is low or no optical power is detected as follows: 
Optical connectors match.
Be careful with cotton and absolute alcohol to clean the fiber optic connector end faces, to be dry before connecting to the unit.
Optical power meter to check the output optical power, confirm whether or between -6 ~ + 2dBm look directly received optical power display.
2, in the optical power of normal conditions, signal quality is poor, check the output level is too high or too low, if the window for debugging.
3, when the power light is off, check the power supply is normal, and then check the fuse is blown.
4, reverse light hair module with optical power indicator (green normal), and can use a multimeter to test the reverse light emitted light power and bias current, typically optical power monitoring of 1v / mw, the bias current of 50mA / 1v If the light indicating normal power, received optical power and optical node abnormalities, make sure:
Optical connectors match.
Be careful with cotton and absolute alcohol to clean the fiber optic connector end faces, to be dry before connecting to the unit.